Publications

  • Manufacturing-Process Dose Estimation for HBM During PCB X-Ray Inspection: Effects of PCB Attenuation, Package Structure, and Backscatter (opens in a new tab)

    S. Baeg, M. Chun, S. H. Chung, J. Kim, G. Bak, and S. H. Jeon

    Electronics, vol. 15, no. 22, Art. no. 5391, Nov. 2026

    Abstract

    This work evaluates the accumulated dose at a High Bandwidth Memory (HBM)-relevant location during printed circuit board (PCB) X-ray inspection under real manufacturing conditions. Measurements used an Omron VT-X750 3D CT X-ray inspection system at 115 kV and 130 μA with 1 mm Al filtration. A silicon PIN diode dosimeter at selected HBM locations recorded the dose rate and accumulated dose during the inspection scan. HBM-relevant exposure was strongly affected by PCB attenuation, HBM/package attenuation, scan position, and backscatter. The 3 mm PCB reduced the dose rate by approximately one order of magnitude relative to the direct-beam reference, and the additional HBM attenuation corresponded to an effective Cu thickness of approximately 0.15–0.16 mm. After PCB transmission, most of the remaining exposure was attenuated in the HBM/package structure. Combining this estimate with the image-sensor-side backscatter gives an HBM-relevant exposure estimate of approximately 75% of the PCB-transmitted exposure (average dose-rate equivalent approximately 0.46 mGy(Si)/s), an operational value derived from detector-dose differences rather than a measured absorbed dose in the HBM dies. The dose-rate waveform showed that exposure at the HBM location accumulates through transient events as the beam scans the PCB. HBM exposure during PCB X-ray inspection cannot be estimated from machine settings or static geometry alone; PCB/package attenuation, scan trajectory, component location, and backscatter must be considered.

  • Comparative Analysis of Failed-Bit Sensitivity to Total Ionizing Dose in DRAM Under X-Ray PCB Inspection (opens in a new tab)

    M. Chun, G. Bak, S. Jeon, and S. Baeg

    IEEE Transactions on Nuclear Science, vol. 73, no. 11, pp. 4246–4258, Nov. 2026

    Abstract

    This work studies how total ionizing dose (TID) damages DDR4 dynamic random access memory (DRAM) components during X-ray printed circuit board (PCB) inspection. To compare radiation sensitivity across different DRAM devices, we introduce the dose sensitivity (DS), defined as the logarithmic ratio of post- to pre-irradiation retention failed-bit counts normalized by the absorbed dose. Retention time measurements were carried out on six DDR4 components from three manufacturers irradiated with a 130-kV X-ray inspection machine at both 45 °C and 85 °C. The analysis is organized around three aspects of DS evaluation: dependence on total dose, manufacturer-dependent radiation sensitivity, and the influence of the dose quantity used in the denominator. Together, these three aspects validate DS as a normalized metric for comparing TID-induced retention degradation. Within a single sample, DS varies by a factor of 5.46× depending only on which of four dose quantities is chosen: the dose measured by a dosimeter or the equilibrium dose, with or without the integrated circuit (IC) package. This variation is comparable in magnitude to the variation between the most and least sensitive components tested (5.25×) at the same retention condition. When the DS values reported under different dose quantities are compared across different components, the two variations can combine multiplicatively, yielding a total range of up to approximately 28.7×, substantially larger than either variation alone. When DS is extrapolated to the JEDEC retention requirement of 64 ms at 85 °C, the ranking of the tested components shifts compared with that obtained in the directly measured 1–20-s range at 45 °C, indicating that DS depends on the temperature and retention time conditions under which it is evaluated. The equilibrium dose is the most consistent choice for cross-study comparison because it is independent of the detector, but it requires knowledge of the X-ray spectrum, which is often not available in practice. For this reason, the dose quantity and the evaluation condition must always be clearly stated when reporting DS values.